One of the leading companies in its field wanted to preserve a recently refurbished rotor. The rotor needed protection for a maximum of two years, until it returned to service. The plan called for placing the rotor in a wooden crate and storing it in an indoor warehouse.
A refurbished rotor represents a significant investment. Machined surfaces on rotors demand tight tolerances, so even light corrosion can cause problems. Rust can affect how the rotor performs once it returns to service.
Indoor storage lowers the risk, but it doesn’t remove it. Warehouses still see humidity and temperature swings. Condensation can form on cold metal, and a wooden crate can hold moisture against the surface.
Long storage periods raise the stakes. A rotor that sits for up to two years needs protection that works without regular checks. A simple, repeatable procedure also helps, since it keeps the process consistent from one rotor to the next.
The team followed a straightforward three-step process.
VpCI®-368:
This coating placed a protective film directly on the rotor’s metal surfaces. Spray application covered the rotor evenly and kept the process quick.
MilCorr® VpCI® Shrink Film:
This film sealed the coated rotor in a tight enclosure. The vapor phase inhibitors in the film added a second layer of protection around the whole part.
The heat gun method:
A portable heat gun shrank the film to a taut fit. This approach kept the equipment simple and let the team work wherever the rotor sat.
The customer was satisfied with the straightforward preservation procedure. As a result, the company decided to start offering preservation services to its own clients.
This project shows how a simple preservation method can protect a high-value part and even create a new service offering. For repair shops and service companies, this case offers several practical lessons:
How do you preserve a refurbished rotor for long-term storage?
Inspect the surface, spray it with VpCI®-368, let it dry, wrap it in MilCorr® VpCI® Shrink Film, and place it in a crate.
How long can this method protect a rotor?
In this project, the customer needed protection for a maximum of two years of indoor warehouse storage.
How do you apply MilCorr® VpCI® Shrink Film?
Wrap the part, then heat the film with a portable heat gun until it shrinks to a taut fit.
Why did the customer start offering preservation services?
The customer was satisfied by how straightforward the procedure was, so the company decided to offer it to its clients.