Cortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notagline
  • ABOUT US
    • VpCI® Technology
    • MCI® Technology
    • The Cortec® Story
    • Engineering and Field Service
    • Cortec® R&D
    • Asset Integrity Assurance
  • INDUSTRIES
    • Oil & Gas
      • Aboveground Storage Tanks
      • Equipment Preservation
      • Hydrotesting and Mothballing
      • Mothballing
      • Cased Pipeline Crossings
      • Rig Stacking
    • Manufacturing Industries
    • Construction
      • Reinforced Concrete Structures
      • Post-Tensioned Structures
      • Concrete Repair
    • Power & Water
      • Above-ground Storage Tanks
      • Equipment Preservation
      • Hydrotesting and Mothballing
      • Mothballing
      • Cased Pipeline Crossings
    • Aviation
  • PRODUCTS
    • All Purpose Lubricant
    • Surface Preparation
    • Rust Preventives
    • VpCI® Powder
    • VpCI® Additives
    • VpCI® Packaging
    • VpCI® Emitters
    • MCI® for Concrete
  • CONTACT US
Home  »  case studies   »   Protecting Annular Apaces of Double Wall Storage Tanks
Published by Cortec Middle East on March 15, 2024
Categories
  • case studies
Tags
  • Protecting Annular Apaces of Double Wall Storage Tanks
Protecting Annular Apaces of Double Wall Storage Tanks

Protecting Annular Apaces of Double Wall Storage Tanks

Protecting Annular Apaces of Double Wall Storage Tanks

Protecting Double Wall Storage Tank Annular Spaces with VpCI®-307

Problem

Conoco Oil needed corrosion protection for the annular spaces of double wall storage tanks. Because these spaces sit between the inner and outer tank walls, they present a genuinely challenging area to protect, requiring a solution capable of delivering reliable, long-term corrosion resistance without complex ongoing maintenance.

Background: Why Annular Spaces in Double Wall Tanks Present a Unique Protection Challenge

Double wall storage tanks provide an added layer of containment safety, but the annular space between the inner and outer walls creates its own corrosion vulnerability. This space often contains backfill material and can trap moisture, creating conditions where standard coatings or treatments applied to accessible tank surfaces simply can’t reach.

Because this space becomes largely inaccessible once tank assembly is complete, any corrosion protection strategy needs to work reliably over the tank’s entire service life without requiring future access for reapplication or maintenance. This makes the choice of protection method during initial construction especially important, since correcting an inadequate approach later would require far more invasive and costly intervention.

Application

Conoco Oil applied VpCI®-307 powder directly to the annular space of the storage tanks. The product offered flexible application options: technicians could mix it with backfill material in dry powder form, or dilute it with water at a concentration range of 1–2.5% by weight, depending on the specific installation requirements.

Why VpCI®-307:
This vapor phase corrosion inhibitor powder could be applied easily to new storage tanks before assembly, integrating corrosion protection directly into the construction process rather than requiring a separate treatment step afterward. Because the product worked effectively whether mixed dry with backfill or diluted with water, it offered flexibility to match different installation methods and site conditions.

Conclusion

VpCI®-307 proved inexpensive and environmentally safe, while also offering effective corrosion protection for the tank annular spaces. Beyond standalone use, the product could also work in conjunction with cathodic protection when desired, giving operators additional flexibility in designing a comprehensive protection strategy.

Based on the success experienced at Conoco Oil, other major oil and chemical companies adopted this same corrosion protection method, including DuPont, Texaco, and Vista Chemical. Notably, Conoco had already been using various Cortec® products for preservation, hydro blasting, and corrosion protection of tubulars before this project. Using their own lab testing procedures, Conoco determined that VpCI®-307 powder delivered the best protection for this specific application.

Why This Case Matters for Storage Tank Construction and Maintenance

This project demonstrates how integrating corrosion protection directly into the construction process can solve challenges that post-installation treatments simply can’t address. For companies designing or maintaining double wall storage tanks, this case highlights several practical lessons:

  • Protection during construction outperforms after-the-fact solutions — applying VpCI®-307 before tank assembly ensured comprehensive coverage of the annular space that would become inaccessible afterward.
  • Flexible application methods suit different construction approaches — offering both dry powder and diluted liquid options allowed the product to adapt to varying installation methods and site conditions.
  • Compatibility with existing protection systems adds value — the ability to use VpCI®-307 alongside cathodic protection gave operators the option to layer protection strategies as needed.
  • Independent testing builds confidence in product selection — Conoco’s own lab testing procedures confirmed VpCI®-307’s superior performance, giving the company strong internal validation before industry-wide adoption followed.

Key Takeaways

  • Double wall storage tank annular spaces present a corrosion protection challenge due to their inaccessibility after construction.
  • VpCI®-307 powder can be applied either mixed with backfill or diluted with water, offering flexible installation options.
  • The product proved inexpensive, environmentally safe, and compatible with cathodic protection systems.
  • Major oil and chemical companies, including DuPont, Texaco, and Vista Chemical, adopted this method following Conoco’s success.
  • Independent lab testing by Conoco confirmed VpCI®-307 as the best-performing solution for this specific application.

Cortec Products Used

  • VpCI®-307
Contact Us
Share
0
Cortec Middle East

Related posts

High Rise Building Restoration

High Rise Building Restoration

September 23, 2025

High Rise Building Restoration


Read more
Protection of Electrical Cabinets

Protection of Electrical Cabinets

September 23, 2025

Protection of Electrical Cabinets


Read more
Cleaning and Preservation of Spare Parts

Cleaning and Preservation of Spare Parts

August 24, 2025

Cleaning and Preservation of Spare Parts


Read more

Comments are closed.

Cortec Middle East-logo

QUICK LINKS

  • → HOME
  • → ABOUT US
  • → INDUSTRIES
  • → PRODUCTS
  • → CAREER
  • → CONTACT US
  • → PRIVACY
  • → MEDIA

REQUEST A WEBINAR

REQUEST NOW

SOCIAL MEDIA

ADDRESS

CORTEC® MIDDLE EAST,
2411 Tower B, Jafza One,
Jebel Ali Freezone, DUBAI,
UNITED ARAB EMIRATES


TEL. +971 4 434 0669
FAX. +971 4 434 0668
INQUIRIES@CORTEC-ME.COM

Copyright Cortec® Middle East.
All rights reserved. Cortec®, MCI®, VpCI® 126-Blue®, EcoFilm®, EcoWorks®, Rawn® and Bull Frog® are registered trademarks of Cortec® Corporation.
    • No translations available for this page

      REQUEST A FREE SAMPLE



        Download Layup Manuals

          Select Manual* :


          Offshore Rig Layup PR




            Layup of Land Based Drilling Rigs PR




              Request a Quote


                Talk To Our Experts


                  Subscribe Now

                    Apply Now

                      Upload Your CV