HRSG tube bundle preservation became essential when a client needed to protect the internal surfaces of ten Heat Recovery Steam Generator tube bundles. STS fabricated the bundles in five different modular designs.
Because hydrotesting introduces water into internal systems, the client needed corrosion protection during the test and continued preservation afterward. In addition, the preservation method needed to protect the internal coil surfaces during the storage period.
Therefore, the project required a solution that combined hydrotest corrosion protection with long-term dry preservation.
Water used during hydrotesting can leave internal metal surfaces vulnerable to corrosion. Therefore, an effective HRSG tube bundle preservation program should address corrosion during hydrotesting and after crews drain the system.
Traditional preservation methods can require operators to maintain controlled internal environments. In this application, however, the client wanted a practical alternative that did not depend on maintaining Superdry air at negative dew points or a nitrogen atmosphere.
As a result, the team selected a combination of VpCI®-649 and VpCI®-309SF.
The team first added VpCI®-649 to the hydrotest water at a concentration of 0.25% by weight. This treatment provided corrosion protection for the internal system during hydrotesting.
After completing the hydrotest, workers drained the water from the system. Next, they air-dried the internal surfaces to prepare them for long-term preservation.
The team then fogged VpCI®-309SF into the coil bundles using compressed air. They applied the product at a rate of 350 g/m³.
Consequently, the two-stage approach addressed both hydrotesting and the subsequent preservation period.
The preservation process followed a clear sequence.
This HRSG tube bundle preservation process allowed the team to protect internal surfaces during two important stages of the project.
Protection During Hydrotesting
The team added VpCI®-649 directly to the hydrotest water. Therefore, corrosion protection began during the hydrotesting process.
Contact and Volatile Corrosion Inhibitors
VpCI®-649 combines contact and volatile corrosion inhibitors with antiscalants.
Non-Toxic Formulation
The formulation is free from nitrates, phosphates, chromates, and heavy metals.
Controlled Dosage
The team maintained a concentration of 0.25% by weight during hydrotesting.
Long-Term Dry Preservation
After draining and air-drying the system, the team used VpCI®-309SF for continued internal protection.
Up to 24 Months of Protection
VpCI®-309SF provided up to 24 months of continuous protection for this application.
Fogging Application
Workers used compressed air to fog the dry powder into the coil bundles.
Volume-Based Dosage
The team applied VpCI®-309SF at 350 g/m³, creating a defined application rate based on internal volume.
The client considered the Cortec® preservation system a practical alternative to traditional methods.
For example, achieving and maintaining negative dew points with Superdry air can be costly and difficult. Likewise, preserving systems under nitrogen requires operators to maintain the protective atmosphere.
In contrast, the selected VpCI® system did not require ongoing maintenance after application. In addition, the specified dosage accounted for minor losses within the system.
Therefore, the preservation strategy simplified long-term protection of the HRSG tube bundles.
A planned HRSG tube bundle preservation strategy can provide protection during hydrotesting and continue protecting internal surfaces afterward.
In this project, VpCI®-649 addressed the hydrotesting stage. Meanwhile, VpCI®-309SF provided dry preservation after workers drained and air-dried the system.
Furthermore, VpCI®-309SF provided up to 24 months of continuous protection. The preservation approach also avoided the need to continuously maintain a Superdry air or nitrogen atmosphere.
As a result, the client received a preservation solution designed around both the testing and storage phases.
The client was satisfied with the combination of the hydrotest additive and dry powder preservation system.
The team used VpCI®-649 at 0.25% by weight during hydrotesting. Afterward, workers drained and air-dried the systems before applying VpCI®-309SF at 350 g/m³.
Most importantly, the HRSG tube bundle preservation approach offered an alternative to maintaining negative dew points with Superdry air or preserving the systems under nitrogen.
VpCI®-309SF also provided up to 24 months of continuous protection without the ongoing maintenance required by the traditional methods considered for the project.
What is HRSG tube bundle preservation?
HRSG tube bundle preservation protects the internal surfaces of Heat Recovery Steam Generator tube bundles against corrosion during hydrotesting and subsequent storage.
Which product protected the system during hydrotesting?
The team added VpCI®-649 to the hydrotest water.
What concentration of VpCI®-649 was used?
The team used VpCI®-649 at 0.25% by weight.
What happened after hydrotesting?
Workers drained the hydrotest water and air-dried the system. Next, they fogged VpCI®-309SF into the coil bundles.
What dosage of VpCI®-309SF was used?
The team applied VpCI®-309SF at 350 g/m³ using compressed air.
How long did VpCI®-309SF provide protection?
The product provided up to 24 months of continuous protection in this application.