Piping internal preservation was essential for Preassembled Racks (PARs) and Preassembled Modules (PAMs) prepared for the UZ-750 project in the UAE.
The company fabricated the modules onshore and then transported them to the Zakum Islands for final fit-up. Because the project required a preservation period of up to two years, the internal surfaces of the piping systems needed reliable protection throughout storage, transportation, and installation.
Furthermore, the piping systems contained different types of metals. Therefore, the preservation program needed suitable products for both carbon steel systems and systems containing yellow metals.
Large offshore projects often fabricate modules onshore before transporting them to their final installation location. During this period, piping systems can remain inactive for long periods.
As a result, the internal metal surfaces require protection throughout the preservation period. The harsh climatic conditions of the Arabian Peninsula added to the project’s preservation requirements.
Moreover, different metallurgy required different preservation products. Therefore, the project team needed to select the appropriate VpCI® treatment for each piping system.
The project team selected Cortec® VpCI® technology for the piping preservation program.
For carbon steel (CS) and low-temperature carbon steel (LTCS) systems, the team fogged VpCI®-609 into the piping internals.
However, systems containing yellow metals required a different treatment. Therefore, the team fogged VpCI®-337 into these systems.
This targeted approach allowed the preservation program to address the different piping materials while supporting the required preservation period of up to two years.
The project required a practical method for protecting internal piping surfaces before the modules reached their final installation stage.
Instead of applying the same product throughout every piping system, the team matched each VpCI® product to the system metallurgy.
For CS and LTCS systems, VpCI®-609 provided the selected preservation treatment. Meanwhile, the team used VpCI®-337 in systems containing yellow metals.
Consequently, the piping internal preservation strategy addressed the different material requirements across the PARs and PAMs.
VpCI®-609 for CS and LTCS Systems
The project team selected VpCI®-609 for carbon steel and low-temperature carbon steel piping. They applied the product by fogging it into the piping systems.
VpCI®-337 for Systems Containing Yellow Metals
The team selected VpCI®-337 for systems that contained yellow metals. They also applied this product by fogging it into the relevant systems.
Protection for an Extended Project Schedule
The modules required preservation for up to two years. Therefore, the preservation plan needed to protect piping internals throughout the extended project period.
Application Across Preassembled Modules
The products supported the preservation requirements of both Preassembled Racks and Preassembled Modules before final offshore fit-up.
A planned piping internal preservation program helps protect valuable piping systems while modules remain inactive before final installation.
In this project, the preservation strategy accounted for different types of piping metallurgy. Furthermore, the use of separate VpCI® products allowed the team to treat CS and LTCS systems differently from systems containing yellow metals.
As a result, the company achieved effective preservation for piping internals during an extended offshore construction schedule.
Cortec® and The Kanoo Group supported the company in protecting piping internals for the UZ-750 project.
The project team used VpCI®-609 for CS and LTCS systems and VpCI®-337 for systems containing yellow metals. This approach provided a targeted piping internal preservation strategy for the project’s PARs and PAMs.
Ultimately, the preservation program helped the company protect piping systems for up to two years under the harsh climatic conditions found in the Arabian Peninsula.
What is piping internal preservation?
Piping internal preservation protects the inside surfaces of piping systems during periods when the systems remain inactive before installation or operation.
Why did the UZ-750 project require piping preservation?
The company fabricated the PARs and PAMs onshore before transporting them to the Zakum Islands for final fit-up. The project required preservation for up to two years.
Which product was used for carbon steel piping?
The project team fogged VpCI®-609 into carbon steel and low-temperature carbon steel systems.
Which product was used for systems containing yellow metals?
The team used VpCI®-337 in piping systems containing yellow metals.
How were the VpCI® products applied?
The team applied both products by fogging them into the relevant piping systems.
How long did the piping require preservation?
The project required a preservation period of up to two years.