Piping internal preservation was essential for Preassembled Modules (PAMs) prepared for the UZ-750 project in the UAE. The company fabricated the modules onshore before transporting them to the Zakum Islands for final fit-up.
The project required preservation for up to two years. Therefore, the team needed a reliable solution that could protect piping internals throughout the extended project period and under the harsh climatic conditions of the Arabian Peninsula.
Furthermore, the piping systems contained different metals. The company wanted one preservation product that could provide long-term multimetal protection across the modules.
Preassembled Modules can remain inactive for long periods between fabrication and final offshore installation. During this time, piping internals require suitable preservation to maintain their condition.
Hydrotesting also introduces water into the piping systems. Consequently, the client needed to drain the systems and remove remaining water before applying the preservation treatment.
For this project, the company needed a piping internal preservation solution that could work across different modules while simplifying the overall preservation approach.
The project team identified VpCI®-337 as the preferred product because it provided the required long-term multimetal protection. In addition, using one product allowed the company to standardize the preservation approach across all modules.
After hydrotesting, the client drained the piping system. Next, the team air-blowed the piping to remove water before applying VpCI®-337.
Once the system was ready, workers fogged VpCI®-337 through the end of each piping module.
The team divided each module into individual test packs. Because the pipe internal diameter and pipe run were known, they calculated the internal piping volume for each test pack.
Finally, the team fogged VpCI®-337 into the system at a dosage of 1 L/m³.
The company wanted to standardize preservation across the Preassembled Modules. Therefore, the team selected VpCI®-337 as the preferred product for the piping systems.
Its long-term multimetal protection allowed the project to use one preservation product across the modules.
Furthermore, the volume-based application method allowed the team to calculate the required quantity for each piping test pack. They used the known pipe diameter and run to determine the internal volume before applying VpCI®-337 at 1 L/m³.
This approach provided a consistent piping internal preservation method across the project’s PAMs.
Long-Term Protection
The project required preservation for up to two years. Therefore, the team needed a product suitable for the extended project schedule.
Multimetal Protection
The company selected VpCI®-337 because it provided multimetal protection across the piping modules.
One Product Across the Modules
The team wanted to unify the preservation approach. Consequently, VpCI®-337 became the preferred product across all modules.
Controlled Application Rate
The team calculated the piping volume and applied the product at 1 L/m³.
Suitable Fogging Application
After draining and air blowing the piping, workers fogged VpCI®-337 through the piping modules.
The project followed a clear preservation sequence:
As a result, the project applied a consistent preservation method across the required piping systems.
A planned piping internal preservation strategy allows offshore construction projects to protect piping during extended periods between fabrication and final installation.
In this project, the modules required up to two years of preservation. Moreover, the company needed a solution that could simplify treatment across piping systems containing different metals.
By selecting VpCI®-337, the project team could standardize the preservation product across all PAMs while maintaining a defined volume-based application method.
Cortec® and Texel Energy Services supported the company in preserving piping internals for the UZ-750 project.
The team selected VpCI®-337 to provide long-term multimetal protection and standardize treatment across the Preassembled Modules. After hydrotesting, workers drained and air-blowed the piping before fogging the product at 1 L/m³.
Ultimately, the piping internal preservation strategy helped the company protect the modules for an extended period under the harsh climatic conditions found in the Arabian Peninsula.
What is piping internal preservation?
Piping internal preservation protects internal metal surfaces while piping remains inactive during storage, transportation, or before final installation.
Why did the UZ-750 project require piping preservation?
The company fabricated the PAMs onshore before transporting them to the Zakum Islands for final fit-up. Therefore, the piping required protection for up to two years.
Which product did the project use?
The team selected VpCI®-337 for long-term multimetal protection.
How was VpCI®-337 applied?
After hydrotesting, the client drained and air-blowed the piping. The team then fogged VpCI®-337 through the piping modules.
What dosage was used?
The team calculated the internal piping volume and applied 1 L of VpCI®-337 per cubic meter.
Why was one product used across the modules?
The company wanted to unify the preservation approach, and VpCI®-337 provided the required multimetal protection.
Texel Energy Services