Cortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notagline
  • ABOUT US
    • VpCI® Technology
    • MCI® Technology
    • The Cortec® Story
    • Engineering and Field Service
    • Cortec® R&D
    • Asset Integrity Assurance
  • INDUSTRIES
    • Oil & Gas
      • Aboveground Storage Tanks
      • Equipment Preservation
      • Hydrotesting and Mothballing
      • Mothballing
      • Cased Pipeline Crossings
      • Rig Stacking
    • Manufacturing Industries
    • Construction
      • Reinforced Concrete Structures
      • Post-Tensioned Structures
      • Concrete Repair
    • Power & Water
      • Above-ground Storage Tanks
      • Equipment Preservation
      • Hydrotesting and Mothballing
      • Mothballing
      • Cased Pipeline Crossings
    • Aviation
  • PRODUCTS
    • All Purpose Lubricant
    • Surface Preparation
    • Rust Preventives
    • VpCI® Powder
    • VpCI® Additives
    • VpCI® Packaging
    • VpCI® Emitters
    • MCI® for Concrete
  • CONTACT US
Home  »  case studies • Oil and Gas   »   Gas Injection Platform (Gip) Preservation
Published by Cortec Middle East on December 11, 2019
Categories
  • case studies
  • Oil and Gas
Tags
drilling rig layup strategy

drilling rig layup strategy

Gas Injection Platform (Gip) Preservation

Gas Injection Platform Equipment Preservation with Cortec® VpCI® Technology

Challenge

Gas injection platform equipment preservation became essential when a company needed to protect critical assets during construction before the offshore platform set sail.

During the construction period, equipment faced two main risks. Corrosion could affect exposed metal surfaces, while construction activities could cause mechanical and physical damage. Therefore, the company needed a preservation system that could protect electrical panels, transformers, sheltered equipment, and assets exposed to harsh outdoor conditions.

In addition, the preservation method needed to support fast commissioning. The company wanted to minimize the work required to remove preservation materials before putting the equipment into service.

Why Gas Injection Platform Equipment Preservation Matters

Offshore platform equipment can remain exposed throughout fabrication, construction, and pre-sail activities. During this period, moisture and corrosive conditions can affect valuable components before the platform even enters operation.

Furthermore, different equipment requires different types of protection. Electrical control panels need internal corrosion protection. Transformers require protection against both corrosion and moisture. Meanwhile, larger equipment needs physical protection from the surrounding construction environment.

For this reason, the gas injection platform equipment preservation strategy used several Cortec® VpCI® products rather than relying on a single preservation method.

Application

The project team recommended Cortec® VpCI® products according to the protection requirements of each asset.

First, workers placed VpCI®-101, VpCI®-105, and VpCI®-111 emitters inside electrical control panels. These products provided protection inside the enclosed electrical spaces.

For transformers, the company required protection against both corrosion and moisture. Therefore, the team recommended Desicorr-VpCI® Pouches to address these requirements.

The team also considered the location of each asset when selecting protective packaging.

Equipment stored under shelter received VpCI®-126 Blue Shrink Film. In contrast, equipment exposed to harsh outdoor conditions received MilCorr® VpCI® Film.

As a result, the preservation approach matched the protection method to the equipment type and its surrounding environment.

Electrical Control Panel Protection

Electrical control panels required internal corrosion protection during the construction period.

Therefore, the team installed VpCI®-101, VpCI®-105, and VpCI®-111 emitters inside the panels. This approach allowed the project to protect electrical components without applying liquid or oil-based preservation products.

Furthermore, the method supported the company’s requirement for limited depreservation before startup.

Transformer Corrosion and Moisture Protection

The transformers required protection against two threats: corrosion and moisture.

To meet both requirements, the team recommended Desicorr-VpCI® Pouches. This solution supported the overall preservation program while addressing the specific requirements of transformer equipment.

Consequently, the project could use a targeted preservation approach rather than applying the same method to every asset.

Protection for Sheltered and Outdoor Equipment

Equipment location also played an important role in product selection.

The team wrapped items stored under shelter with VpCI®-126 Blue Shrink Film. The film provided protective packaging for assets that remained within sheltered construction areas.

However, equipment stored in harsh outdoor conditions required a different solution. Therefore, workers wrapped these assets with MilCorr® VpCI® Film.

This approach provided different levels of protection based on actual storage and environmental conditions.

Why Cortec® VpCI® Technology Was Chosen

Limited Depreservation
One of the main advantages was the limited amount of depreservation required before equipment entered service. This helped support an efficient transition from preservation to operation.

No Liquids or Oils
The selected preservation approach did not require liquids or oils for the protected applications. Therefore, the company could avoid additional cleanup associated with these preservation methods.

Protection for Different Equipment Types
The project included electrical panels, transformers, sheltered equipment, and outdoor assets. Consequently, the team selected different VpCI® solutions according to each application’s requirements.

Corrosion and Moisture Protection
Desicorr-VpCI® Pouches addressed the need for both corrosion and moisture protection in transformers.

Protection During Construction
VpCI®-126 Blue Shrink Film and MilCorr® VpCI® Film provided protective wrapping for equipment during the construction period.

Immediate Product Availability
The required products were immediately available. In addition, the supplier supported the project through a Just In Time supply model that accommodated the company’s working schedule and environment.

Benefits of Gas Injection Platform Equipment Preservation

A planned gas injection platform equipment preservation program can protect critical assets before an offshore facility enters service.

In this project, the team used targeted solutions for electrical panels, transformers, sheltered assets, and equipment exposed to harsh outdoor conditions.

Furthermore, the selected products supported limited depreservation before commissioning. The absence of liquid and oil-based preservation products in these applications also simplified the transition to service.

As a result, the company could protect valuable equipment throughout construction while keeping future commissioning requirements in mind.

Conclusion

Cortec® VpCI® technology provided a practical preservation solution for equipment on the gas injection platform during construction.

The project team protected electrical control panels with VpCI® emitters and used Desicorr-VpCI® Pouches where both moisture and corrosion presented concerns. Meanwhile, VpCI®-126 Blue Shrink Film protected sheltered items, while MilCorr® VpCI® Film protected equipment in harsh outdoor conditions.

Most importantly, the gas injection platform equipment preservation strategy supported quick depreservation before the assets entered service. In addition, immediate product availability and Just In Time supply helped accommodate the project’s working schedule and environment.

Why This Case Matters for Offshore Operators

  • Preservation can begin during platform construction, before the facility enters offshore service.
  • Different assets require different corrosion protection methods.
  • Electrical control panels can receive targeted internal protection.
  • Transformers may require both moisture and corrosion protection.
  • Sheltered and outdoor equipment require different protective packaging.
  • Limited depreservation can simplify the transition from construction to operation.
  • Just In Time product availability can support demanding project schedules.

Frequently Asked Questions

What is gas injection platform equipment preservation?
Gas injection platform equipment preservation protects critical assets from corrosion and physical damage during construction and before the platform enters service.

How were electrical control panels protected?
The team placed VpCI®-101, VpCI®-105, and VpCI®-111 emitters inside the electrical control panels.

How were the transformers protected?
The project team recommended Desicorr-VpCI® Pouches because the transformers required protection against both corrosion and moisture.

How was sheltered equipment protected?
Workers wrapped equipment stored under shelter with VpCI®-126 Blue Shrink Film.

How was outdoor equipment protected?
The team used MilCorr® VpCI® Film for items exposed to harsh outdoor conditions.

Why was fast depreservation important?
The customer wanted to limit the work required before placing the protected equipment into service.

Key Takeaways

  • The company needed corrosion and physical protection during platform construction.
  • The preservation period occurred before the gas injection platform set sail.
  • VpCI®-101, VpCI®-105, and VpCI®-111 protected electrical control panels.
  • Desicorr-VpCI® Pouches addressed corrosion and moisture concerns in transformers.
  • VpCI®-126 Blue Shrink Film protected equipment stored under shelter.
  • MilCorr® VpCI® Film protected equipment in harsh outdoor conditions.
  • The selected approach required limited depreservation before service.
  • The supplier provided immediately available materials through a Just In Time model.

Distributor

The Kanoo Group

Cortec® Products Used

  • VpCI®-101
  • VpCI®-105
  • VpCI®-111 Emitters
  • Desicorr-VpCI® Pouches
  • VpCI®-126 Blue Shrink Film
  • MilCorr® VpCI® Shrink Film
Contact Us
Share
0
Cortec Middle East

Related posts

High Rise Building Restoration

High Rise Building Restoration

September 23, 2025

High Rise Building Restoration


Read more
Protection of Electrical Cabinets

Protection of Electrical Cabinets

September 23, 2025

Protection of Electrical Cabinets


Read more
Cleaning and Preservation of Spare Parts

Cleaning and Preservation of Spare Parts

August 24, 2025

Cleaning and Preservation of Spare Parts


Read more

Comments are closed.

Cortec Middle East-logo

QUICK LINKS

  • → HOME
  • → ABOUT US
  • → INDUSTRIES
  • → PRODUCTS
  • → CAREER
  • → CONTACT US
  • → PRIVACY
  • → MEDIA

REQUEST A WEBINAR

REQUEST NOW

SOCIAL MEDIA

ADDRESS

CORTEC® MIDDLE EAST,
2411 Tower B, Jafza One,
Jebel Ali Freezone, DUBAI,
UNITED ARAB EMIRATES


TEL. +971 4 434 0669
FAX. +971 4 434 0668
INQUIRIES@CORTEC-ME.COM

Copyright Cortec® Middle East.
All rights reserved. Cortec®, MCI®, VpCI® 126-Blue®, EcoFilm®, EcoWorks®, Rawn® and Bull Frog® are registered trademarks of Cortec® Corporation.
    • No translations available for this page

      REQUEST A FREE SAMPLE



        Download Layup Manuals

          Select Manual* :


          Offshore Rig Layup PR




            Layup of Land Based Drilling Rigs PR




              Request a Quote


                Talk To Our Experts


                  Subscribe Now

                    Apply Now

                      Upload Your CV