Cortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notagline
  • ABOUT US
    • VpCI® Technology
    • MCI® Technology
    • The Cortec® Story
    • Engineering and Field Service
    • Cortec® R&D
    • Asset Integrity Assurance
  • INDUSTRIES
    • Oil & Gas
      • Aboveground Storage Tanks
      • Equipment Preservation
      • Hydrotesting and Mothballing
      • Mothballing
      • Cased Pipeline Crossings
      • Rig Stacking
    • Manufacturing Industries
    • Construction
      • Reinforced Concrete Structures
      • Post-Tensioned Structures
      • Concrete Repair
    • Power & Water
      • Above-ground Storage Tanks
      • Equipment Preservation
      • Hydrotesting and Mothballing
      • Mothballing
      • Cased Pipeline Crossings
    • Aviation
  • PRODUCTS
    • All Purpose Lubricant
    • Surface Preparation
    • Rust Preventives
    • VpCI® Powder
    • VpCI® Additives
    • VpCI® Packaging
    • VpCI® Emitters
    • MCI® for Concrete
  • CONTACT US
Home  »  case studies   »   Extending Service Life of Stay Cables
Published by Cortec Middle East on June 12, 2024
Categories
  • case studies
Tags
  • Extending Service Life of Stay Cables
Extending Service Life of Stay Cables

Extending Service Life of Stay Cables

Extending Service Life of Stay Cables

Filling Cable Voids on the Cochrane Bridge with MCI® Mini Grenades

Problem

Inspectors detected voids in the “stay” cables on the Cochrane Bridge in Mobile, Alabama. They used video scope inspection to examine the cables. Through this process, they found some cable strands exposed with no grout cover. As a result, these critical structural elements became vulnerable to corrosion.

Background: Why Cable-Stayed Bridge Maintenance Demands Precise Corrosion Solutions

Cable-stayed bridges rely on high-strength steel strands to carry significant structural loads. Typically, grout encases these strands to protect them from moisture and corrosion. When voids develop in this grout coverage, exposed cable strands lose their protective barrier entirely. This creates a direct pathway for corrosion to begin on components that are difficult and expensive to inspect or replace.

Because stay cables play such a critical structural role, any repair approach needs to restore both the physical grout coverage and the corrosion protection that coverage originally provided. Given the specialized nature of cable-stayed bridge construction, repair materials also need to integrate seamlessly with existing grouting systems. Otherwise, they risk compromising the grout’s essential performance characteristics.

Application

The repair team began by measuring the voids. Next, they filled them using vacuum grouting methods, a technique well-suited to reaching enclosed cable spaces without disturbing the surrounding structure. To enhance corrosion protection, the Alabama Department of Transportation then approved using MCI® Mini Grenades alongside DSI’s DYNA Grout. This added an extra layer of protection to the standard grouting material.

Why MCI® Mini Grenades:
These products deliver concentrated Migrating Corrosion Inhibitor protection directly into the grout mixture. As a result, they enhance the corrosion resistance of the repair without requiring a separate application step. Because they integrate directly into the DYNA Grout during vacuum grouting, they protected the newly exposed cable strands as soon as the repair material filled the voids.

Conclusion

The MCI® Mini Grenades mixed well with the DYNA Grout and did not alter its flow properties. Thanks to this compatibility, the repair team could add corrosion protection to the grouting system without compromising the grout’s ability to properly fill and seal the cable voids.

Why This Case Matters for Cable-Stayed Bridge Maintenance

This project demonstrates how a corrosion inhibitor can integrate directly into existing repair materials without disrupting their essential performance. For engineers and transportation departments managing cable-stayed bridge infrastructure, this case highlights several practical lessons:

  • Compatibility with existing repair materials matters — MCI® Mini Grenades worked seamlessly with DSI’s DYNA Grout, avoiding the need for an entirely new repair system.
  • Vacuum grouting effectively addresses hard-to-reach voids — this method allowed the team to fill cable voids precisely without disturbing surrounding structural elements.
  • Adding corrosion protection to standard repairs extends structural life — enhancing DYNA Grout with MCI® technology addressed both the immediate void and the underlying corrosion risk in a single repair.
  • Regulatory approval confirms repair reliability — AL-DOT’s approval of this combined approach reflects confidence in the compatibility and performance of the enhanced grouting system.

Key Takeaways

  • Voids in stay cable grout coverage expose critical structural strands to corrosion risk.
  • Vacuum grouting methods effectively fill cable voids without disturbing surrounding structure.
  • MCI® Mini Grenades add corrosion protection directly into grout mixtures without altering flow properties.
  • Compatibility between corrosion inhibitors and existing repair materials simplifies implementation for transportation departments.
  • Regulatory approval, such as from AL-DOT, confirms the reliability of combined repair approaches for critical infrastructure.

Cortec Products Used

  • MCI® Mini Grenades
Contact Us
Share
0
Cortec Middle East

Related posts

High Rise Building Restoration

High Rise Building Restoration

September 23, 2025

High Rise Building Restoration


Read more
Protection of Electrical Cabinets

Protection of Electrical Cabinets

September 23, 2025

Protection of Electrical Cabinets


Read more
Cleaning and Preservation of Spare Parts

Cleaning and Preservation of Spare Parts

August 24, 2025

Cleaning and Preservation of Spare Parts


Read more

Comments are closed.

Cortec Middle East-logo

QUICK LINKS

  • → HOME
  • → ABOUT US
  • → INDUSTRIES
  • → PRODUCTS
  • → CAREER
  • → CONTACT US
  • → PRIVACY
  • → MEDIA

REQUEST A WEBINAR

REQUEST NOW

SOCIAL MEDIA

ADDRESS

CORTEC® MIDDLE EAST,
2411 Tower B, Jafza One,
Jebel Ali Freezone, DUBAI,
UNITED ARAB EMIRATES


TEL. +971 4 434 0669
FAX. +971 4 434 0668
INQUIRIES@CORTEC-ME.COM

Copyright Cortec® Middle East.
All rights reserved. Cortec®, MCI®, VpCI® 126-Blue®, EcoFilm®, EcoWorks®, Rawn® and Bull Frog® are registered trademarks of Cortec® Corporation.
    • No translations available for this page

      REQUEST A FREE SAMPLE



        Download Layup Manuals

          Select Manual* :


          Offshore Rig Layup PR




            Layup of Land Based Drilling Rigs PR




              Request a Quote


                Talk To Our Experts


                  Subscribe Now

                    Apply Now

                      Upload Your CV