Cortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notagline
  • ABOUT US
    • VpCI® Technology
    • MCI® Technology
    • The Cortec® Story
    • Engineering and Field Service
    • Cortec® R&D
    • Asset Integrity Assurance
  • INDUSTRIES
    • Oil & Gas
      • Aboveground Storage Tanks
      • Equipment Preservation
      • Hydrotesting and Mothballing
      • Mothballing
      • Cased Pipeline Crossings
      • Rig Stacking
    • Manufacturing Industries
    • Construction
      • Reinforced Concrete Structures
      • Post-Tensioned Structures
      • Concrete Repair
    • Power & Water
      • Above-ground Storage Tanks
      • Equipment Preservation
      • Hydrotesting and Mothballing
      • Mothballing
      • Cased Pipeline Crossings
    • Aviation
  • PRODUCTS
    • All Purpose Lubricant
    • Surface Preparation
    • Rust Preventives
    • VpCI® Powder
    • VpCI® Additives
    • VpCI® Packaging
    • VpCI® Emitters
    • MCI® for Concrete
  • CONTACT US
Home  »  News   »   Cortec’s Advanced MCI® Technology Creates Longer Service Life for Existing Overpasses and Bridges
Published by Cortec Middle East on December 11, 2019
Categories
  • News
Tags
cortec advanced mci technology

Cortec’s Advanced MCI® Technology Creates Longer Service Life for Existing Overpasses and Bridges

Bridge Corrosion Protection with MCI® Technology

Overview

Bridge corrosion protection with MCI® technology provides a proactive way to protect reinforcing steel embedded in concrete. Bridges and overpasses often face carbonation, humidity, salt exposure, pollution, and other aggressive environmental conditions that can accelerate reinforcement corrosion.

Once corrosion begins, rust expands around the reinforcing steel. Consequently, the surrounding concrete can crack and spall. Over time, this deterioration can reduce durability and increase repair requirements.

Cortec® Migrating Corrosion Inhibitors (MCI®) help address these challenges. Engineers can use MCI® as a surface treatment on existing concrete or add it directly to new concrete as an admixture.

How MCI® Technology Protects Reinforcing Steel

MCI® technology moves through concrete pores toward embedded reinforcing steel.

The inhibitor ions adsorb onto the metal surface and create a monomolecular protective layer. Therefore, the technology helps protect reinforcement against oxygen, chlorides, and other corrosive contaminants.

Moreover, MCI® products provide both anodic and cathodic corrosion protection.

Unlike surface treatments that only restrict contaminant ingress, certain MCI® treatments migrate through the concrete to protect the reinforcement below the surface.

Why Bridge Corrosion Protection Matters

Reinforced concrete bridges face several potential sources of deterioration.

For example, carbonation can lower concrete pH and affect the natural protective environment surrounding freshly embedded reinforcement. Meanwhile, humid conditions, salt spray, pollution, and other aggressive exposure can increase corrosion risks.

Once steel begins to corrode, expanding corrosion products place pressure on the surrounding concrete. As a result, cracking and spalling can occur.

Therefore, bridge corrosion protection with MCI® technology can support a broader strategy for improving concrete durability and extending service life.

MCI® Protection Throughout the Bridge Life Cycle

Engineers can use MCI® products at several stages of a bridge’s life cycle, including:

  • New construction
  • Concrete repair
  • Preventive maintenance
  • Protection of existing structures

However, proactive application before significant corrosion develops can provide an important advantage.

Rather than waiting for extensive deterioration, owners can introduce corrosion protection as part of planned maintenance or construction.

Osijek Overpass Case Study

Cortec® Case History 536 demonstrates the use of MCI® surface treatments on an existing overpass in Osijek, Croatia.

The customer wanted to help protect the bridge against future corrosion. At the same time, the project aimed to improve the bridge’s appearance.

Therefore, the project team selected two treatments:

  • MCI®-2020 Powder
  • MCI® Architectural Coating

Together, these products provided corrosion protection while also giving the overpass a refreshed appearance.

Surface Preparation

First, workers water-blasted the concrete surfaces.

This process removed dirt, oil, grease, and other contaminants. Next, the team allowed the concrete to dry before applying the corrosion protection system.

Proper preparation created a clean surface for the subsequent treatments.

Applying MCI®-2020 Powder

After the concrete dried, workers brushed a solution of MCI®-2020 Powder onto the overpass.

Next, they allowed the treatment to dry for 24 hours.

The MCI® treatment travels through pores within the concrete toward the embedded reinforcement. Consequently, it creates corrosion protection directly at the reinforcing steel.

This characteristic differentiates the treatment from systems that only create a barrier at the concrete surface.

Furthermore, if cracking develops in the concrete, the protective treatment remains at the rebar surface according to the supplied case information.

Benefits of MCI®-2020 Powder

MCI®-2020 Powder provides several advantages for reinforced concrete protection.

First, the Migrating Corrosion Inhibitors travel through the concrete toward embedded reinforcement.

In addition, the product forms a protective layer at the reinforcing steel rather than functioning solely as a surface barrier.

The supplied product information also describes MCI®-2020 Powder as:

  • Organic
  • Environmentally friendly
  • Free from calcium nitrite

Therefore, the product combines reinforcement protection with environmental benefits.

Applying MCI® Architectural Coating

After applying MCI®-2020 Powder, the project team coated the overpass with MCI® Architectural Coating in light grey.

The coating gave the bridge a cleaner, refreshed appearance. More importantly, it added another layer of protection.

The topcoat incorporated corrosion-inhibiting technology and provided sealant protection against:

  • Carbonation
  • Moisture
  • Chlorides
  • Other contaminants

Furthermore, the supplied information describes MCI® Architectural Coating as water-based, non-toxic, and non-flammable.

As a result, the project combined reinforcement-level protection with an external protective coating.

Dual Bridge Corrosion Protection with MCI® Technology

The Osijek project used two complementary protection methods.

First, MCI®-2020 Powder migrated through the concrete toward the embedded reinforcement.

Next, MCI® Architectural Coating provided additional surface protection while improving the appearance of the concrete.

Therefore, bridge corrosion protection with MCI® technology addressed both embedded steel protection and external concrete protection.

This dual approach prepared the overpass for improved durability and an extended service life.

Testing and Performance of MCI®-2020 Powder

According to the supplied technical information, evaluations have demonstrated the performance of MCI®-2020 Powder.

The product has undergone evaluation connected with the Strategic Highway Research Program (SHRP) and other documented field evaluations.

The supplied information also references:

  • ASTM G109
  • Industrial standards and evaluations in Japan and Korea
  • NSF Standard 61 for potable water applications

These references support the broader technical background behind the product’s use for reinforced concrete corrosion protection.

Performance of MCI® Architectural Coating

The supplied information reports that MCI® Architectural Coating decreased chloride-induced corrosion of metal reinforcement fourfold based on Cortec® Project #00-285-4431.

In addition, testing on SAE 1010 carbon steel reported:

  • 168 hours of protection in an ASTM B117 salt spray chamber
  • More than 1,000 hours in an ASTM D1748 humidity chamber

For aluminum at a 2 mil DFT, the supplied information reports more than 1,000 hours of protection in both salt spray and humidity chambers.

Furthermore, the product information states that MCI® Architectural Coating conforms to ASTM D7234, which covers pull-off adhesion testing of coatings on concrete.

Benefits of Bridge Corrosion Protection with MCI® Technology

A planned bridge corrosion protection with MCI® technology strategy can address corrosion at different stages of a structure’s life.

For existing bridges, surface-applied MCIs can migrate through concrete toward embedded reinforcement.

In addition, architectural coatings can provide another protective layer against moisture, chlorides, carbonation, and other contaminants.

For new structures, engineers can also incorporate appropriate MCI® products directly into the concrete as admixtures.

Consequently, MCI® technology offers options for new construction, repair, and maintenance applications.

Why This Case Matters for Bridge Owners and Engineers

  • Reinforcement corrosion can cause concrete cracking and spalling.
  • Carbonation can reduce the protective environment surrounding embedded steel.
  • In addition, salt, humidity, and contaminants can increase corrosion risks.
  • MCI® products can protect reinforcement below the concrete surface.
  • Engineers can use MCI® technology during construction, repair, or maintenance.
  • The Osijek overpass used MCI®-2020 Powder and MCI® Architectural Coating.
  • Workers allowed MCI®-2020 Powder to dry for 24 hours before proceeding.
  • Furthermore, the Architectural Coating provided additional protection against carbonation, moisture, chlorides, and contaminants.
  • The combined system also improved the appearance of the overpass.

Frequently Asked Questions

What are Migrating Corrosion Inhibitors?
Migrating Corrosion Inhibitors are corrosion protection technologies that move through concrete pores toward embedded reinforcing steel.

How does MCI® help protect bridge reinforcement?
MCI® ions migrate toward reinforcing steel and adsorb onto its surface. Consequently, they form a protective layer against corrosive influences.

Can MCI® technology protect existing bridges?
Yes. The supplied information describes surface treatments for existing concrete as well as admixtures for new concrete.

Which products did the Osijek overpass use?
The project used MCI®-2020 Powder followed by MCI® Architectural Coating.

How did workers prepare the bridge?
First, they water-blasted the concrete to remove dirt, oil, and grease. Then they allowed the surface to dry before applying MCI®-2020 Powder.

How long did MCI®-2020 Powder dry?
The project allowed the MCI®-2020 Powder treatment to dry for 24 hours.

What did the Architectural Coating add?
The coating provided a light-grey finish and additional protection against carbonation, moisture, chlorides, and contaminants.

Key Takeaways

  • Bridge corrosion protection with MCI® technology can protect embedded reinforcing steel.
  • MCIs travel through concrete pores toward the reinforcement.
  • Therefore, they can provide protection below the concrete surface.
  • Engineers can use MCI® products during construction, repair, and maintenance.
  • Cortec® Case History 536 involved an overpass in Osijek, Croatia.
  • First, workers cleaned the concrete through water blasting.
  • Next, they applied MCI®-2020 Powder and allowed it to dry for 24 hours.
  • Afterward, they applied light-grey MCI® Architectural Coating.
  • Consequently, the system combined reinforcement protection with additional surface protection.
  • The project also improved the appearance of the existing overpass.

Cortec® Products Used

  • MCI®-2020 Powder
  • MCI® Architectural Coating
Contact Us
Share
0
Cortec Middle East

Related posts

Air Cooler Preservation in the Middle East

Air Cooler Preservation in the Middle East

September 18, 2026

Air Cooler Preservation in the Middle East


Read more
Heater Preservation in the Middle East

Heater Preservation in the Middle East

September 11, 2026

Heater Preservation in the Middle East


Read more
Valve Preservation in Oil & Gas

Valve Preservation in Oil & Gas

August 21, 2026

Valve Preservation in Oil & Gas


Read more

Comments are closed.

Cortec Middle East-logo

QUICK LINKS

  • → HOME
  • → ABOUT US
  • → INDUSTRIES
  • → PRODUCTS
  • → CAREER
  • → CONTACT US
  • → PRIVACY
  • → MEDIA

REQUEST A WEBINAR

REQUEST NOW

SOCIAL MEDIA

ADDRESS

CORTEC® MIDDLE EAST,
2411 Tower B, Jafza One,
Jebel Ali Freezone, DUBAI,
UNITED ARAB EMIRATES


TEL. +971 4 434 0669
FAX. +971 4 434 0668
INQUIRIES@CORTEC-ME.COM

Copyright Cortec® Middle East.
All rights reserved. Cortec®, MCI®, VpCI® 126-Blue®, EcoFilm®, EcoWorks®, Rawn® and Bull Frog® are registered trademarks of Cortec® Corporation.
    • No translations available for this page

      REQUEST A FREE SAMPLE



        Download Layup Manuals

          Select Manual* :


          Offshore Rig Layup PR




            Layup of Land Based Drilling Rigs PR




              Request a Quote


                Talk To Our Experts


                  Subscribe Now

                    Apply Now

                      Upload Your CV