Cortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notaglineCortec-Middle-East-logo-notagline
  • ABOUT US
    • VpCI® Technology
    • MCI® Technology
    • The Cortec® Story
    • Engineering and Field Service
    • Cortec® R&D
    • Asset Integrity Assurance
  • INDUSTRIES
    • Oil & Gas
      • Aboveground Storage Tanks
      • Equipment Preservation
      • Hydrotesting and Mothballing
      • Mothballing
      • Cased Pipeline Crossings
      • Rig Stacking
    • Manufacturing Industries
    • Construction
      • Reinforced Concrete Structures
      • Post-Tensioned Structures
      • Concrete Repair
    • Power & Water
      • Above-ground Storage Tanks
      • Equipment Preservation
      • Hydrotesting and Mothballing
      • Mothballing
      • Cased Pipeline Crossings
    • Aviation
  • PRODUCTS
    • All Purpose Lubricant
    • Surface Preparation
    • Rust Preventives
    • VpCI® Powder
    • VpCI® Additives
    • VpCI® Packaging
    • VpCI® Emitters
    • MCI® for Concrete
  • CONTACT US
Home  »  case studies   »   Boiler and Hot Well Corrosion Protection
Published by Cortec Middle East on April 29, 2022
Categories
  • case studies
Tags
Untitled design (9)

Boiler and Hot Well Corrosion Protection

Eliminating Corrosion in Boiler Production with VpCI®-645 and VpCI®-309

Problem

TPK Nova, located in Zagreb, Croatia, stands as the largest producer of boilers and hot wells in the region. Despite this leading position, the company faced numerous corrosion problems during testing, shipping, and storage. These problems slowed down production, and worse, they led to complaints from customers receiving affected equipment.

Background: Why Pressure Testing Creates Corrosion Risk for Boiler Manufacturers

Boiler and hot well manufacturers rely on pressure testing to verify equipment integrity before shipment. This process typically fills the equipment with water, which confirms it can handle operating pressure safely. However, this same water introduces a corrosion risk the moment testing ends.

Once technicians drain the test water, moisture remains on internal metal surfaces. If the equipment sits for any length of time before drying completely, rust can begin forming almost immediately. This creates a frustrating cycle: the very process meant to confirm product quality ends up introducing a defect of its own.

For TPK Nova, this problem extended beyond testing into shipping and storage as well. Equipment that passed pressure testing successfully could still arrive at a customer’s site showing corrosion, damaging the company’s reputation and slowing down overall production as teams dealt with rework and complaints.

Application

TPK Nova built corrosion protection directly into its testing and finishing process. During pressure testing, the company used Cortec® VpCI®-645, designing a closed system where the test water itself contained the corrosion inhibitor. This meant protection began at the exact moment testing started, rather than after the fact.

Once testing finished and the equipment dried, the team fogged Cortec® VpCI®-309 inside the boilers and hot wells. This step added a second layer of protection, specifically suited to the equipment’s enclosed internal spaces. With both treatments complete, the boilers and hot wells were ready for shipping and storage.

Why Each Product Was Chosen

VpCI®-645:
Mixed directly into the pressure testing water, this product protected internal surfaces from the very start of the testing process. Because the inhibitor was already present during testing, it eliminated the gap between test completion and corrosion protection that had previously caused problems.

VpCI®-309:
Applied by fogging after the equipment dried, this product reached enclosed internal spaces that liquid treatment alone might miss. It gave TPK Nova a reliable way to protect the equipment through the full shipping and storage period that followed.

Conclusion

TPK Nova chose Cortec® products as their corrosion protection solution because no competitor could offer a solution this environmentally safe, effective, and easy to use. As a result, TPK Nova achieved excellent results in eliminating corrosion, increasing production, and preserving customer retention.

Why This Case Matters for Boiler and Pressure Vessel Manufacturers

This project shows how building corrosion protection into the testing process itself can solve a problem that traditional post-test treatment often misses. For boiler, hot well, and pressure vessel manufacturers, this case offers several practical lessons:

  • Protection should start during testing, not after — treating the test water directly with VpCI®-645 closed the gap where corrosion previously began.
  • Enclosed spaces need their own protection method — fogging VpCI®-309 reached internal areas that testing alone couldn’t cover.
  • Corrosion problems affect more than product quality — TPK Nova saw slower production and customer complaints, showing how corrosion issues ripple through an entire operation.
  • Environmental safety and performance can align — the company selected Cortec specifically because its solution combined effectiveness with environmental responsibility.

Frequently Asked Questions

How do you prevent corrosion during boiler pressure testing?
Add a corrosion inhibitor, such as VpCI®-645, directly into the pressure testing water. This protects internal surfaces from the moment testing begins.

What causes corrosion in boilers after pressure testing?
Moisture remaining on internal surfaces after draining test water can trigger rust, especially if the equipment doesn’t dry completely before storage or shipment.

How do you protect enclosed boiler spaces after testing?
Fog a vapor phase corrosion inhibitor, such as VpCI®-309, inside the equipment once it dries. This reaches internal spaces that liquid treatments may not fully cover.

Why did TPK Nova choose Cortec® products over competitors?
No competitor could match Cortec’s combination of environmental safety, effectiveness, and ease of use for this application.

Key Takeaways

  • TPK Nova faced corrosion problems during testing, shipping, and storage, which slowed production and led to customer complaints.
  • VpCI®-645 mixed into pressure testing water protected equipment from the start of the testing process.
  • VpCI®-309 fogged into dried equipment added protection for enclosed internal spaces.
  • Cortec’s combination of environmental safety and effectiveness set it apart from competing solutions.
  • The new process helped eliminate corrosion, increase production, and preserve customer retention for TPK Nova.

Cortec Products Used

  • VpCI®-645
  • VpCI®-309
Contact Us
Share
6
Cortec Middle East

Related posts

High Rise Building Restoration

High Rise Building Restoration

September 23, 2025

High Rise Building Restoration


Read more
Protection of Electrical Cabinets

Protection of Electrical Cabinets

September 23, 2025

Protection of Electrical Cabinets


Read more
Cleaning and Preservation of Spare Parts

Cleaning and Preservation of Spare Parts

August 24, 2025

Cleaning and Preservation of Spare Parts


Read more

Comments are closed.

Cortec Middle East-logo

QUICK LINKS

  • → HOME
  • → ABOUT US
  • → INDUSTRIES
  • → PRODUCTS
  • → CAREER
  • → CONTACT US
  • → PRIVACY
  • → MEDIA

REQUEST A WEBINAR

REQUEST NOW

SOCIAL MEDIA

ADDRESS

CORTEC® MIDDLE EAST,
2411 Tower B, Jafza One,
Jebel Ali Freezone, DUBAI,
UNITED ARAB EMIRATES


TEL. +971 4 434 0669
FAX. +971 4 434 0668
INQUIRIES@CORTEC-ME.COM

Copyright Cortec® Middle East.
All rights reserved. Cortec®, MCI®, VpCI® 126-Blue®, EcoFilm®, EcoWorks®, Rawn® and Bull Frog® are registered trademarks of Cortec® Corporation.
    • No translations available for this page

      REQUEST A FREE SAMPLE



        Download Layup Manuals

          Select Manual* :


          Offshore Rig Layup PR




            Layup of Land Based Drilling Rigs PR




              Request a Quote


                Talk To Our Experts


                  Subscribe Now

                    Apply Now

                      Upload Your CV